Purchasing Office in USA!

For USA brands, Direct shipping from USA to worldwide destination!
Product Detail
AEMC 6417 Ground Clamp Meters
Category:
▶ AEMC
keyWord:
AEMC 6417 Ground Clamp Meters
Describe:
AEMC 6417
Contact us
Description
http://www.jinstartech.com/
General Attributes:
AEMC 6417 very good price
Ground Resistance Tester Model 6417 (Clamp-on, Bluetooth, Alarm, Memory, DataView Software) {ETL}
- Touch voltage display - alerts the user to potential unsafe conditions
- Large multi-function, bright yellow organic display (OLED) usable in all lighting conditions
- Display in Standard mode (1 screen) or Advanced mode (3 screens)
- Selectable test frequency improves accuracy in inductive environments
- Differentiates between loop and ground resistance measurements
- Data storage (Ω and/or A, with time-stamping): Stores up to 2000 measurements
- Displays stored measurements on the OLED display or via Bluetooth to a PC or the Android-based mobile application. (Model 6417)
- Easy clamp opening by a force compensation trigger system
- Large jaw design, 1.38" (35mm) accommodating up to 1000kcmil cables
- Alarm function with an adjustable set point and buzzer for quick field checks
Description
- Display: OLED, 152 segments 48x39mm
- Memory: 2000 measurements
- Communication: Bluetooth, DataView software included
- Alarm: 3 separate alarms (Ω, V and A)
- Jaw Opening: 1.38” (35mm) max
- Operating Temperature: -4° to +131°F (-20 to +55°C)
- Storage Temperature: -22° to +158°F (-30 to +70°C)
Ground Clamp Meters
The Ground Resistance Tester Model 6417 measures ground rod and grid resistance and impedance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting or de-energizing the ground system under test. The Model 6417 simply clamps around the grounding electrode or conductor and measures the resistance to the ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.
Three new features unique to AEMC are:
- Test frequency selection provides more accurate results in inductive environments
- Touch voltage indication indicates the voltage on the display along with a warning buzzer when the voltage derived from current and resistance measurements detects a potentially dangerous touch condition
- Loop resistance indication alerts the user to the fact that the measurement may not be ground resistance
The Ground Resistance Tester Models 6416 and 6417, measure ground rod and grid resistance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting the ground system under test or de-energizing them. Models 6416 and 6417 simply clamp around the ground conductor or rod and measure the resistance to the ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.
Two new features unique to AEMC are tested frequency selection and touch voltage indication. The ability to select the test frequency provides more accurate results in inductive environments. Displaying voltage derived from current and resistance measurements provides an extra level of safety for the user, indicating a potentially dangerous touch condition. Both models include a current measurement function. The probe’s high sensitivity enables measurement of leakage current flowing to the ground or circulating in ground loops from 0.2mA to 40A and resistances from 0.01 to 1500Ω.
Both models offer battery life information at power-up and Auto-Off for power management. Additional features are also displayed on the large OLED display to ensure precise measurements. The Buzzer and Auto-Off Power features may be disabled from the push-buttons at any time.
Both offer an alarm function and a data storage function. In the Alarm Mode, the probe will audibly and visually indicate if the reading is beyond the user-programmed set point. The user may have the alarm activated above or below the set point. This alarm feature permits quick field checks where only “pass” or “fail” readings are required.
The data storage function enables the user to conduct field surveys and to retrieve and analyze the readings at a later time. The alarm settings and stored data are saved when the ground tester is turned off. The 6417 provides Bluetooth transmission to a PC for analysis and report generation via the included DataView software.
Manufacturer Specs
AEMC 6417 Specifications | |||
ELECTRICAL | |||
Ground Resistance Auto-Ranging 0.01 to 1500Ω |
Measurement Range | Resolution | Accuracy (% of Reading) |
0.010 to 0.099Ω | 0.001Ω | ±1.5% ±0.01O | |
0.10 to 0.99Ω | 0.01Ω | ±1.5% ±0.01O | |
1.0 to 49.9Ω | 0.1Ω | ±1.5% ±0.1O | |
50.0 to 99.5Ω | 0.5Ω | ±2% ±0.5O | |
100 to 199Ω | 1OΩ | ±3% ±1O | |
200 to 395Ω | 5Ω | ±5% ±5O | |
400 to 590Ω | 10Ω | ±10% ±10O | |
600 to 1150Ω | 50Ω | 20% approx | |
1200 to 1500Ω | 50Ω | 25% approx | |
Current Measurement Auto-Ranging 0.2mA to 40A |
0.200 to 0.999mA | 1µA | ±2% ±50µA |
1.000 to 2.990mA 3.00 to 9.99mA |
10µA | ±2% ±50µA | |
10.00 to 29.90mA 30.0 to 99.9mA |
100µA | ±2% ±100µA | |
100.0 to 299.0mA 0.300 to 0.990A |
1mA | ±2% ±1mA | |
1.000 to 2.990A 3.00 to 39.99A |
10mA | ±2% ±10mA | |
Resistance Measurement Frequency |
50, 60, 128 or 2083Hz (user selectable) | ||
Current Measurement Frequency |
47 to 800Hz | ||
Power Source | 4x1.5V LR6 (AA) Alkaline batteries or 4 NiMH batteries; Battery life: 12 hours, or 14,400 30-second measurements approx |
||
Data Storage | Model 6416: 300 measurements; Model 6417: 2000 measurements |
||
MECHANICAL | |||
Dimensions | 2.16 x 3.74 x 10.31” (55 x 9 x 262mm) | ||
Weight | 2.06 lbs (935g) approx. with batteries | ||
Jaw Opening | 1.38” (35mm) max | ||
Display | Multi-function, bright yellow organic display (OLED) | ||
ENVIRONMENTAL | |||
Operating Temperature | -4° to 131°F (-20° to 55°C) | ||
Operating Humidity | 10% to 90% RH | ||
SAFETY | |||
Safety Rating | EN 61010-1 (Ed. 2 of 2001); 600V CAT IV |
Tech Specs
Ground Testers/Ground Clamp Meters Template |
|
---|---|
Maximum Ground Resistance | 1500 Ohms (1.5 K Ohms) |
Minimum Ground Resistance | 0.01 Ohms |
Resolution | 0.001 Ohms |
Resistance Measurement Frequency | 2083 Hz |
Current Measurement Frequency | 800 Hz |
Maximum Current Range | 40 A |
Display Hold | Yes |
Resistance Accuracy | +/-1.5% +/-.01 |
Jaw Capacity Conductor Size | 35 MM (39.37 IN) |
CAT Rating | IV |
CAT Voltage | 600 V |
Alarms | Yes |
Test Equipment General Attributes |
|
Unique Features | ETL approved loop impedance detection OLED display voltage/resistance/ current measurement and alarm indication ground voltage detection test frequency selection Bluetooth Class 2 inductance measurement |
Warranty | 12 MONTHS (1 YEARS) |
Safety Approval | CE |
Interfaces I/O | Bluetooth |
Storage | Compact Flash |
IP Rating | IP40 |
Product Weight | 2.06 LBS |
Product Height | 2.16 IN |
Product Length | 10.31 IN |
Product Width | 3.74 IN |
Shipping Weight | 9.00 LBS |
Data Logging | No |
HTS/Schedule B Number | 9030.33.3400 |
ECCN Number | EAR99 |
Calibration Included | Factory Calibration |
Battery Type | AA |
Power Supply Voltage | Battery Powered |
Country of Origin | France |
UPC | 68538130492 |