Purchasing Office in USA!

Global

For USA brands, Direct shipping from USA to worldwide destination!

NEWS

Do you have a Fluke, GE/Druck, Martel, or Transmation calibrator and need an upgrade to PIE?


www.jinstartech.com

For USA brands, Shipping from our USA Purchasing office directly to worldwide destination

 

Do you have a Fluke, GE/Druck, Martel, or Transmation calibrator and need an upgrade to PIE?

Use the below cross reference guide to find the recommended PIE replacement.

A Fluke calibrator for process instruments is large with lots of buttons versus the small size and easy to use interface of a PIE Calibrator. The Fluke 725 and Fluke 726 process calibrators require complicated hookups with easily lost jumper wires for RTD connections while the PIE 820 & PIE 830 use true 2, 3 & 4 wire connections. The Fluke 714, Fluke 714B thermocouple calibrators and the Fluke 724 Thermocouple/RTD calibrator require miniature thermocouple connectors to plug in wires while the PIE 422 and PIE 525B accept bare thermocouple wires under screws as well as miniature thermocouple connectors.

Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Fluke process calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.

Upgrade to PIE

Type

Fluke Model

PIE Model

Multifunction

Fluke 725

PIE 830

Multifunction

Fluke 726

PIE 830

Thermocouple

Fluke 714

PIE 422

RTD

Fluke 712

PIE 311

Thermocouple & RTD

Fluke 724

PIE 525B

Milliamp

Fluke 705

PIE 334

Milliamp

Fluke 707

PIE 434

Milliamp

Fluke 709

PIE 434

Milliamp & Voltage

Fluke 715

PIE 532

Thermocouple & mA

Fluke 714B

PIE 422Plus

RTD & mA

Fluke 712B

PIE 311Plus

RTD, Thermocouple & mA

Fluke 724

PIE 525Plus

 

A GE Calibrator or Druck Calibrator is complicated versus the small size and easy to use interface of a PIE Calibrator. The DPI 811 and DPI 812 and DPI 880 calibrators require complicated hookups with easily lost jumper wires for RTD connections while the PIE 820 & PIE 830 use true 2, 3 & 4 wire connections. The Druck DPI 821 and Druck 822 thermocouple calibrators require miniature thermocouple connectors to plug in wires while the PIE 422 and PIE 525B accept bare thermocouple wires under screws as well as miniature thermocouple connectors.

Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Fluke process calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.

Upgrade to PIE

Type

GE Sensing/Druck Model

PIE Model

Multifunction

GE/Druck DPI 880

PIE 830

Thermocouple

GE/Druck DPI 821 or GE/Druck DPI 822

PIE 422

RTD

GE/Druck DPI 811 or GE/Druck DPI 812

PIE 311

Milliamp

GE/Druck UPS II

PIE 334

Milliamp

GE/Druck UPS III

PIE 434

Milliamp & Voltage

GE/Druck DPI 832

PIE 532

Frequency

GE/Druck DPI 841 or GE/Druck DPI 842

PIE 541

Thermocouple & mA

GE/Druck 822

PIE 422Plus

RTD & mA

GE/Druck 812

PIE 311Plus

 

As of 2021 Martel Calibrators are no longer being manufactured. Support is limited as service and replacement parts become harder to find. This includes several models which were labeled under other brand names.

A Martel Calibrator is large with lots of buttons versus the small size and easy to use interface of a PIE Calibrator. The Martel MC-1010 and Martel MC-1210 process calibrators require complicated hookups with easily lost jumper wires for RTD connections while the PIE 820 & PIE 830 use true 2, 3 & 4 wire connections. The Martel PTC-8010 Thermocouple/RTD calibrator require miniature thermocouple connectors to plug in wires while the PIE 525B accept bare thermocouple wires under screws as well as miniature thermocouple connectors.

Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Martel calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.

Upgrade to PIE

Type

Martel Model

PIE Model

Multifunction

Martel MC-1210

PIE 830

Multifunction

Martel MC-1010

PIE 820

Multifunction 10-50mA

Martel MC-1210-50

PIE 850

Thermocouple

Martel TC-100

PIE 422

Thermocouple & RTD

Martel PTC-8010

PIE 525B

Milliamp

Martel LC-110

PIE 434

Milliamp

Martel LC-100

PIE 334

Milliamp

Martel MS-420

PIE 334

Milliamp & Voltage

Martel PSC-4010 or Martel IVC-222HPII

PIE 532

10-50 Milliamp & Voltage

Martel PSC-4010-50

PIE 535 

 

Transmation calibrators have been around since the late 1960s. The first milliamp calibrators had analog meter movements and were housed in extruded aluminum enclosures that were large and heavy. The Transmation 1040 became a standard for instrument technicians even though the digits on the LCD display were the size of a digital watch display. The Transmation 1040, and the Transmation 1080 combined a 4 to 20 milliamp, 10 to 50 milliamp, and voltage calibrator into one device. These were discontinued in 2001.

Other discontinued models include the Transmation 1060, 1061, 1062, 1064P and 1065-MTC thermocouple calibrators, Transmation 1074 and CheckMate 500 RTD calibrators, Transmation 1021, 1022, 1027, 1028, 1030, 1143, 1180 and CheckMate 100 milliamp calibrators, 1188 & CheckMate 100 multifunction calibrator and the Transmation 1070 & 1174 frequency calibrators. Many of these models are so old they that replacement parts no longer exist and are no longer repairable. Or for the models that can be repaired, the cost of repair often exceeds the cost of a replacement PIE calibrator!

When you check the accuracy of some of these obsolete calibrators you will find that they are no longer accurate enough to calibrate modern process instruments. Why risk using a piece of test equipment designed in the 1970s or 1980s to calibrate a state-of-the-art control system.

Transmation calibrators also used miniature banana jacks that required non-standard test leads and many of them contained expensive rechargeable battery packs. PIE Calibrators use standard, replaceable “AA” and 9V batteries and have standard banana jacks and come with standard test leads. Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Transmation process calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.

Upgrade to PIE

Type

Transmation Model

PIE Model

Multifunction

Transmation CheckMate 1000

PIE 820

Multifunction

Transmation 1188

PIE 830

Thermocouple

Transmation CheckMate 400

PIE 322-1

Thermocouple

Transmation 1064P, 1060, 1061 & 1062

PIE 322-1

Thermocouple

Transmation 1065-MTC

PIE 422

RTD

Transmation 1074

PIE 311

RTD

Transmation CheckMate 500

PIE 311

RTD

Transmation 1173

PIE 311

Milliamp

Transmation CheckMate 100, 1021, 1022, 1027, 1028 & 1030

PIE 334

Milliamp

Transmation 1143

PIE 434

Milliamp

Transmation 43

PIE 434

Milliamp (4-20) & Voltage

Transmation 1040, 1045, 1080 or 1180

PIE 532

Milliamp (10-50) & Voltage

Transmation 1048

PIE 535 (out of stock)

Milliamp (10-50) & Voltage

Transmation 1040 or 1080

PIE 535 (out of stock)

Voltage

Transmation CheckMate 200

PIE 235

Frequency

Transmation 1070, 1173 or CheckMate 300

PIE 541

 

We Sell full range of PIE products, at good discount rate.

 

 

*Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible

SUBMIT

NEWS

CAE Blue Phantom Musculoskeletal (MSK) ultrasound training model

CAE Healthcare releases first musculoskeletal ultrasound training model for joint injections of the knee

Powertek Calibration Services

Powertek offer a range of electrical calibration and repair services for customers requiring continued after sales support for our products.

Milwaukee MA957 Regulator Set-Up Procedure & Gas Flow Adjustment

MA957 Regulator Set-Up Procedure & Gas Flow Adjustment

Hirschmann SPIDER III Unmanaged DIN Rail Fast/Gigabit Ethernet Switches

Select a Standard or Premium Line unmanaged switch to meet your needs

PPB MEGASONICS pb-500 Ultrasonic Meter, 0 to 500 kHz

PPB MEGASONICS pb-500 Ultrasonic Meter, 0 to 500 kHz

CAE Blue Phantom

In 2012, CAE Healthcare acquired Blue Phantom to further expand and enhance simulation-based clinical training and the delivery of patient care globally. Today, CAE Blue Phantom produces the world's most realistic and durable anatomical task trainers. Coupled with a commitment to customer service and quality, CAE is recognized as the leader in ultrasound training models.